During the visit, Xu Jianyi, general manager of the group, Dong Chunbo, deputy general manager, Wang Lizhi, general manager of the liberation company, Xu Xianzhi, secretary of the party committee, and Dai Zhi, deputy general manager of the group met with the visitors and introduced the visitors to the FAW Group and the FAW Jiefang Company. The production and operation status. The two parties negotiated the development of heavy-duty engines, heavy-duty engines and heavy-duty transmissions in the areas of further cooperation and reached consensus. Xu Jianyi, general manager of the group company, and Tan Xuguang, chairman of the company, gave each other gifts. Dong Chunbo, deputy general manager of the group company, and Zhang Quan, Weichai Power executive president, signed the Strategic Cooperation Agreement between China First Automobile Group Corporation and Weichai Power Co., Ltd. . Visitors also visited the truck factory assembly line.

The visit of Chairman of the Weichai Power Group Chairman Tan Xuguang and his party strengthened the cooperative relationship between Liberation Company and Weichai Power and played a positive role in further promoting the friendly cooperation between the two parties.

Metal Body Square Water Cooling Tower

This series of products run stable, low noise, energy-saving, in office buildings, shopping malls, hotels, residential areas and other central air-conditioning supporting the use of better results.

The company's standard cooling tower according to the international design conditions design, can also provide customers with non-standard operating conditions or specific sizes under the special, special design.

The circulating water pump suction port shall be located below the water level of the cooling tower catchment basin, and the cooling tower outlet pipe shall not be allowed to be higher than the maximum water level of the catchment basin.
Pipe mounts should be pipe racks and cooling towers should not be allowed to directly bear the weight of the pipes.

The rehydration pipe of the cooling tower should be provided with a support stand to avoid vibration of the pipe when the float valve is rehydrated.

Rehydration pressure should be below 5m water pressure, national standard
The flannage pressure is 1.0Mpa.

When two or more units are assembled, our company will provide a connecting balance tube to balance the chassis water level. The tower top inlet should be set with a conditioning valve in order to enter each
.The water level of the tower is uniform.


The noise is measured at dm1.13VL-W at the equivalent diameter of the cooling tower (Dm1.13VL*W), 1.5 meters above the ground height, wherein L and W are the shape rulers of the tower
inch long and wide).

The use of cellular continuous blister series of diversion,heat dissipation, water collection three-in-one native filler, the whole suspension, gravity cloth water, low drop of water, with cold effect
High, low energy consumption, less drift water, less noise and so on, floating water rate is less than 0.001%.

When connecting different types of towers, the bottom basin water level height of different types of towers must be taken into account, and the base height must be adjusted to maintain the water level balance of the towers.