SYD-265B-1 Reverse-Flow Viscosity Tester

Model NO.: SYD-265B-1
Viscometer Reproducibility: ±0.2%
Viscometer Rotor Number: 4
Viscometer Rotor Speed: 60r/min
Viscometer Rotor Specifications: 4 Size
Measurement Range: (10~2000000)MPa@S
Spindle: No.1~No.4,Four Kinds of Spindle
Measuring Accuracy: ±2 % (F.S)
Trademark: TBT
Specification: ASTM
Origin: Nanjing, China
HS Code: 90158790
Model NO.: SYD-265B-1
Viscometer Reproducibility: ±0.2%
Viscometer Rotor Number: 4
Viscometer Rotor Speed: 60r/min
Viscometer Rotor Specifications: 4 Size
Measurement Range: (10~2000000)MPa@S
Spindle: No.1~No.4,Four Kinds of Spindle
Measuring Accuracy: ±2 % (F.S)
Trademark: TBT
Specification: ASTM
Origin: Nanjing, China
HS Code: 90158790
SYD-265B-1 Kinematic viscosity / Reverse-flow viscosity / Viscosity index 
Summary
    This instrument is designed and made as per the national standard of People's Republic of China GB/T265 Petroleum products-Determination of kinematic viscosity and calculation of dynamic viscosity, GB/T 11137 Black petroleum products-Determination of kinematic viscosity(reverse-flow method) and calculation of dynamic viscosity and GB/T 1995 Petroleum products-Calculation of viscosity index. It is used to determine the kinematic viscosity of liquid petroleum products (Newtonian liquids) and the kinematic viscosity of dark petroleum products. It can also be used to determine the viscosity index of lubricating oils.
 
I. Main technical features
1. Multifunctional. It can determine the kinematic viscosity of liquid petroleum products (Newtonian liquids) and the kinematic viscosity of dark petroleum products. It can also be used to determine the viscosity index of lubricating oils.
2. Micro-processor control and colored LCD technology. Chinese-English bilingual menu. GUI touch screen. Easy to operate. 
3. Advanced digital control and display. Automatic kinematic viscosity determination
4. It can test 2 samples at a time. The parameters such as temperature, time, coefficient of capillary viscometer tube can be inputted in or displayed on the screen. 
5. New-type temperature sensor. The temperature resolution is 0.01ºC. Temperature control precision is ±0.05ºC. 6. It can save 99 coefficients of capillary viscometer.
 
II. Main technical specifications
1.Capacity of bath:    240mm×280mm
2.Temperature range:    Ambient to 100ºC
3.Temperature resolution:    0.01ºC
4.Temperature control precision:  ±0.05ºC
5. Timing precision:   ±0.1s
6. Display:   5.6 inch colored LCD
7. Sample amount:   2 samples
8. Power supply:   AC(220±10%)V, 50Hz±1Hz
9. Maximum power consumption:  750W
10. Working environment:   Ambient temp.:(15~35)ºC ,RH <85%
11. Dimension:   535mm×440mm×550mm
12. Net weight:   23kg
 
SYD-265-3 Capillary Viscometer Washer
Summary
    The instrument is designed and made specially for washing the capillary viscometers, which are used for testing petroleum products. It can be used to wash glass capillary viscometer of various types, such as Pinkevitch viscometer, Ubbelohde viscometer, Cannon-Fenske routine viscometer, Cannon-Fenske opaque viscometer. It is high-efficient and time saving especially for the capillary viscometers, which are used for testing heavy oil with high viscosity.  
    It adopts micro-controller control technology, program control, automatic washing. It needs less solvent oil and it is convenient, efficient. It can be widely used in the enterprises producing and using petroleum products, colleges and universities, and scientific research institutes and so on, where capillary viscometer are used.
 
I. Main technical specifications
1. Power supply: AC 220V±10%, 50 Hz
2. Maximum power consumption: 700 W
3. Water bath temperature control range: Ambient to 80 ºC
4. Ambient temperature: Room temperature~35ºC
5. Relative humidity: ≤85%
6. Dimension of washer: 320mm×300mm×500mm ( excluding the aspirator )
7. Net weight of washer: 10Kg (excluding the aspirator)
SYD-265B-1 Kinematic viscosity / Reverse-flow viscosity / Viscosity index 
Summary
    This instrument is designed and made as per the national standard of People's Republic of China GB/T265 Petroleum products-Determination of kinematic viscosity and calculation of dynamic viscosity, GB/T 11137 Black petroleum products-Determination of kinematic viscosity(reverse-flow method) and calculation of dynamic viscosity and GB/T 1995 Petroleum products-Calculation of viscosity index. It is used to determine the kinematic viscosity of liquid petroleum products (Newtonian liquids) and the kinematic viscosity of dark petroleum products. It can also be used to determine the viscosity index of lubricating oils.
 
I. Main technical features
1. Multifunctional. It can determine the kinematic viscosity of liquid petroleum products (Newtonian liquids) and the kinematic viscosity of dark petroleum products. It can also be used to determine the viscosity index of lubricating oils.
2. Micro-processor control and colored LCD technology. Chinese-English bilingual menu. GUI touch screen. Easy to operate. 
3. Advanced digital control and display. Automatic kinematic viscosity determination
4. It can test 2 samples at a time. The parameters such as temperature, time, coefficient of capillary viscometer tube can be inputted in or displayed on the screen. 
5. New-type temperature sensor. The temperature resolution is 0.01ºC. Temperature control precision is ±0.05ºC. 6. It can save 99 coefficients of capillary viscometer.
 
II. Main technical specifications
1.Capacity of bath:    240mm×280mm
2.Temperature range:    Ambient to 100ºC
3.Temperature resolution:    0.01ºC
4.Temperature control precision:  ±0.05ºC
5. Timing precision:   ±0.1s
6. Display:   5.6 inch colored LCD
7. Sample amount:   2 samples
8. Power supply:   AC(220±10%)V, 50Hz±1Hz
9. Maximum power consumption:  750W
10. Working environment:   Ambient temp.:(15~35)ºC ,RH <85%
11. Dimension:   535mm×440mm×550mm
12. Net weight:   23kg
 
SYD-265-3 Capillary Viscometer Washer
Summary
    The instrument is designed and made specially for washing the capillary viscometers, which are used for testing petroleum products. It can be used to wash glass capillary viscometer of various types, such as Pinkevitch viscometer, Ubbelohde viscometer, Cannon-Fenske routine viscometer, Cannon-Fenske opaque viscometer. It is high-efficient and time saving especially for the capillary viscometers, which are used for testing heavy oil with high viscosity.  
    It adopts micro-controller control technology, program control, automatic washing. It needs less solvent oil and it is convenient, efficient. It can be widely used in the enterprises producing and using petroleum products, colleges and universities, and scientific research institutes and so on, where capillary viscometer are used.
 
I. Main technical specifications
1. Power supply: AC 220V±10%, 50 Hz
2. Maximum power consumption: 700 W
3. Water bath temperature control range: Ambient to 80 ºC
4. Ambient temperature: Room temperature~35ºC
5. Relative humidity: ≤85%
6. Dimension of washer: 320mm×300mm×500mm ( excluding the aspirator )
7. Net weight of washer: 10Kg (excluding the aspirator)

Prepainted Galvanized Steel Coil

Here you can find the related products in Prepainted Galvanized Steel Coil, we are professional manufacturer of Prepainted Galvanized Steel Coil and Prepainted Galvalume Steel Coil. We focused on international export product development, production and sales. We have improved quality control processes of Ppgil Coil and Galvalume Coil to ensure each export qualified product.
If you want to know more about the products in Prepainted Galvanized Steel Coil, please click the product details to view parameters, models, pictures, prices and other information about Pr epainted Galvanized Steel Sheet and Prepainted Galvalume Coil.

Whatever you are a group or individual, we will do our best to provide you with accurate and comprehensive message about Ppgi.

Prepainted Galvanized Steel Coil,Pre Painted Galvanized Steel Sheet,Prepainted Galvalume Steel,Prepainted Galvalume Coil,Ppgi Coil

Shandong Longhao Steel Group Co., Ltd. , https://www.longhaosteelgr.com