Shanghai Fang Yong electric temperature control valve use and maintenance methods

With the rapid development of our country's industry, electric thermostatic valve is more and more widely used in metallurgy, petrochemical and other fields. Its stability and reliability are also becoming more and more important. Its working status will directly affect the automatic Control process, Shanghai Fanggong Valve Co., Ltd. will elaborate on the use of electric temperature control valve and maintenance. 1. Installation and use precautions Newly designed and installed control system, in order to ensure that the electric thermostat valve can work normally while driving, and make the system safe operation, the new valve should be installed before, check the nameplate mark on the valve and the design Requirements match. The following items should also be debugged. Basic error limit; full stroke deviation; backlash; dead zone; leakage (in demanding occasions). If the original system is overhauled control valve, in addition to the above-mentioned verification, but also the old valve should be stuffing box and connections and other parts of a tightness check. Regulating valve in the field of use, often not because of the quality of the control valve itself, but rather caused by the improper installation of the control valve, such as the installation environment, the installation location and direction of improper or unclear pipe and other causes. Therefore, the installation of electric control valve should pay attention to the following aspects: (1) The regulating valve is a field instrument, the ambient temperature should be -25 ~ 60 ℃, relative humidity ≤ 95%. If it is installed in open air or high temperature occasions, should take waterproof, cooling measures. In the place with the source to stay away from the vibration source or increase the anti-vibration measures. (2) The control valve should generally be installed vertically, under special circumstances can be tilted, such as a large tilt angle or the valve itself is too heavy when the valve should be increased support protection. (3) Generally, do not install the control valve pipe from the ground or the floor is too high, the pipe height is greater than 2m should be set as the platform, in order to facilitate the operation of the hand wheel and easy maintenance. (4) dynamic balance of electric control valve should be installed before the pipeline cleaning, remove dirt and welding slag. After installation, in order to ensure that no impurities remain in the valve body, the valve should also be cleaned again, that is, the medium should be opened so that all valves open to prevent impurities stuck. After using the hand wheel mechanism should be restored to the original neutral position. (5) In order to make the control valve in the event of failure or maintenance of the production process can continue, the control valve should be bypassed. At the same time should also pay special attention to the installation position of the valve is in line with the process requirements. (6) The electric part of the electric thermostatic valve should be installed according to the requirements of the electrical equipment construction. In the case of explosion-proof products, they should be installed in accordance with the "Installation Specification for Electrical Equipment in Explosion Hazardous Locations". Such as the scene wire SBH or other six-core or eight core, outer diameter of about Φ11.3mm rubber mounting cable. In the use of maintenance, in the explosive place is strictly prohibited open cover repair and blasting face pry. At the same time do not knock in the disassembly or scratch explosion-proof surface, after repair to restore the original flameproof state. (7) After the actuator reducer repair should pay attention to refueling lubrication, low-speed motor generally do not demolition and refueling. Assembly should also check the valve position and valve position opening instructions are consistent. 2 common fault location and analysis of the reasons for the dynamic performance of the side valve dynamic balance valve performance will directly affect the quality of the entire regulatory system. As the regulating valve in the field is in direct contact with the medium to be adjusted, the working environment is very poor, so easy to produce a variety of failures. In the production process, in addition to ruled out these failures at any time, but also must be regular maintenance and regular maintenance. Especially for the use of particularly harsh environment control valve, but should pay attention to maintenance and regular maintenance. Different forms of control valve, the failure and its causes are not the same. Sichuan Instrument Factory is now produced straight stroke electric control valve as an example to illustrate the general failure of electric control valve and maintenance methods. 2.1 Servo amplifier Servo amplifier normal working condition: (1) no input signal, there should be no output voltage. (2) Open loop dead zone current ≤160μA (Ⅱ type is 100μA). (3) When the input signal is> 240μA (type 150μA), the output load voltage is 205 ~ 220VAC. (4) The output voltage is basically symmetrical. If the servo amplifier is not working properly, each part may have the following situations: (1) Front magnetic amplifier ① When there is no signal input, the output of the dual-shot magnetic amplifier can be adjusted to zero through the potentiometer W101. Can not be zero may be: A, W101 desoldering transformer or damaged. B, resistance R110, R111 and electrolytic capacitors C101, C102 Weld or desoldering. C, diodes D105 ~ D108 Weld or damaged. D, the offset current is not normal. E, AC winding asymmetry. ② There is input signal, but no output or output asymmetry may be: A, transformer B301 for the AC winding current secondary voltage asymmetry. B, the resistance of the resistors R110 and R111 has changed, the electrolytic capacitors C110, C111 damaged. C, AC excitation winding short circuit. D, diode D105 ~ D108 in some of the tube damage or Weld. ?? 2) Trigger input, one side of the trigger on the oscilloscope screen should have a pulse signal to change the polarity of the input signal, the other side of the trigger pulse signal. The trigger pulse number and amplitude of two groups should be basically the same. Otherwise there are the following situations. ① no input signal (front magnetic amplifier in normal working condition), the output trigger pulse may be: A, trigger pulse output side of the transistor damage, or c, e very Weld. B, resistance R204, R205, R208, R209 resistance has changed. ② input signal, the output without trigger pulse, may be: A, no output pulse side of the transistor, single junction tube damage. B, no output pulse side of the pulse transformer primary or secondary open circuit or short circuit. C, no output pulse side of the diode (D207 or D208) short circuit. The output trigger pulse is not normal There are several phenomena: A, no signal when the two sets of triggers have a pulse output, plus the signal are normal, may be electrolytic capacitors C202 or C203 Weld. B, the beginning of the trigger output on both sides are normal, after a period of work, the output pulse gradually disappear, monosomy tube may have problems. C, the output appears positive and negative pulses, it may be diode D207, D208 was punctured or Weld. (3) After the above inspection and maintenance, the servo amplifier should work normally without any fault in the control loop. Otherwise, there are the following two situations: ① Without input signal, the output voltage (voltage approaching 220VAC) may be: A, thyristor SCR1, SCR2 damage. B, the capacitor C301, C302 is breakdown. ② When there is input signal, there is no output signal or the output voltage is low, it may be: A, D301 ~ D308 diodes have breakdown. B, thyristor SCR1, SCR2 damage. 2.2 regulating valve When the input 4 ~ 20mA signal, the regulating valve stem in the rated stroke with the signal changes up and down freely. If it can not operate normally, it may have the following faults: ① The operating handwheel feels abnormal. A. It feels too light. It may be that the handwheel latch is off or broken. B, feeling too heavy or spinning. There is a foreign body in the reducer jam; spool and bushing or stuck with the valve seat; stem serious bending. ② input 4 ~ 20mA signal, the control valve does not move. A, the system wiring is wrong. B, the motor phase-split capacitor CD is damaged. C, motor wiring open. D, the spool off or stem breakage (at this time the actuator has an action) ③ input 4 ~ 20mA signal, regulating valve can not go through the rated travel. A, differential transformer position is not adjusted. B, some of the diodes D701 ~ D712 are damaged. C, transistor BG701 damaged. (4) other failures in the field. ① valve turbulence, tweets. A, the sensitivity is too high, the implementing agencies have oscillations. B, the fluid pressure changes too much, the actuator thrust is not enough. C, the choice of control valve, the valve often work in a small opening. D, the direction of flow of medium and valve closing direction. E, near the impact of other sources, support instability. F, spool and bushing wear serious. ② valve slow action. A, the media is too viscous, clogging or coking phenomenon. B, filler aging, packing pressed too tight. ③ large amount of leakage. A, spool or valve seat is corroded and worn. B, the seat is loose or the thread is corroded. C, seat, spool foreign body. D, the valve starting point (electric open) or the end (electric closed) is not adjusted. ④ packing and the upper and lower bonnet junction leakage. A, packing gland did not compress. B, PTFE filler aging deterioration. C, stem damage. D, tighten the nut loose. E, seal damage. The correct use and maintenance of the electric thermostatic valve can not only improve the reliability of the process control but also increase the service life of the electric control valve and have considerable economic benefits to the enterprise in terms of energy saving and consumption reduction. Company Name: Shanghai Fanggong Valve Industry Technology Co., Ltd. Tel: Fax: Technical Support: Mr.Ye MSN: E-mail: Website: Address: Shanghai Golden Park all the way No. 1359

Gesket is also called as static seal. It is a mechanical element use to prevent the leakage of fluid between the two components which are static or doesn't have relative motion. 


Fiber/ Sealing Gasket:A gasket is a thin plate (typically disk-shaped) with a hole (typically in the middle) that is normally used to distribute the load of a threaded fastener, such as a screw or nut. 

Gasket is also called as static seal. It is a mechanical element use to prevent the leakage of fluid between the two components which are static or doesn't have relative motion. While Oil Seal also called as dynamic seal is use to prevent leakage of fluid between two components having relative rotary or sliding motion.

A gasket is primarily used to seal two mating surfaces. It prevents leakage of fluids. Washers on the other hand are used primarily to spread pressure evenly, and are used in places of high vibration.


Rubber Gaskets

Rubber Gaskets,Paper Gasket,Ptfe Gasket,Sponge Gasket

Zhejiang Dream Industry Limited , https://www.mlwdream.com