1. The bearings and gears in the pump speed increasing box are lubricated with the method of injecting gear oil. When the user is in use, they should first read the oil dipstick. Whether they are in the calibrated oil level range, if they do not match, they should be added or Release gear oil.
2. Before the pump works, check whether the liquid in the pump is full. If it is not enough, fill the pump with liquid and do not allow liquid to be carried out to avoid damaging the mechanical seal and open the valves of the suction line and output line.
3. Strictly inspect the installation in the suction pipeline. Never allow a leak in the suction pipeline. Otherwise, it cannot be self-priming.
4, pay attention to check the rotation direction is correct.
5. Pay attention to the readings of the pressure gauge and vacuum gauge. After the pump is started, the pressure gauge and the vacuum gauge are indicated to be stable after a period of fluctuations, indicating that the pump has been filled with liquid and the pump has entered the normal infusion.
6. If a strong vibration and noise occur during pump operation, it may be due to cavitation. The main cause of vapor cloudiness is due to excessive flow or too high suction stroke. If the flow rate is too large, the output line control valve can be adjusted to increase the reading of the pressure gauge. If the suction stroke is too high, you should try to reduce the suction height as much as possible.
7. When the pump is finished working, first close the output line control valve and then stop the prime mover.
8. In the cold season, when the pump is not in operation, the pump liquid should be discharged from the drain valve to prevent freezing of the box.
9. When pumping petrol inflammable and explosive medium, it is necessary to do a good job of preventing the electrostatic grounding of pumps and pipes to ensure safety.
10. If the pump is to be used for a long period of time, it should be disassembled, cleaned of parts, and coated with a layer of rust preventive oil on each processing surface, and then assembled for proper storage.
11, mechanical seals in the case of no leakage, do not have to open inspection, disassembly mechanical seals should be gently, pay attention to clean, protect the dynamic, static ring surface, non-collision. The main reasons for the leakage of mechanical seals are caused by moving and static ring mirrors. The repair method can grind the sealing face and restore the mirror. In addition, if the rubber seal is improperly installed or deteriorated, the mechanical seal may leak. At this point, you should carefully install, adjust, or replace the new rubber seal.
12. Pump disassembly sequence.
The pump removal sequence is as follows:
(1) Unscrew the oil drain screw, open the drain valve, drain the pump's residual fluid and gearbox oil, remove the pipe and frame bolts, and remove the pump.
(2) Remove the inlet flange.
(3) Remove the impeller nut and remove the first stage impeller (right-hand pump, left-hand nut). If it is difficult to remove the impeller, remove it when the second stage impeller is removed in the next step.
(4) Remove the coupling nut between the gear box and the pump body. Use M12 bolts to screw M12 bolts into the top screw hole. The two bolts should evenly and slowly push the pump body and gear box top open. At this time, the first stage impeller can be automatically taken out. (Note: The nut of the first stage impeller must be Spin off, the rotary pump is a left-hand nut, the left-hand pump is a right-hand nut, and then the second-stage impeller, and the mechanical seal is separated from the pump body together with the gear.
(5) Remove the middle casing, pull out the second stage impeller, and remove the mechanical seal and seal seat. Pay attention to protect the dynamic and static ring mirror surfaces of the mechanical seal without scratches.
(6) After removing the gear box cover and the input bearing cover, the input shaft is driven out of the box body from the pump body side, and the drive gear is taken out from above the box body. The assembly sequence is the reverse of the disassembly sequence above. Where there is a triangular seal ring, the gap must be uniform around the impeller, and the impeller does not wipe the pump box.