Model NO.: ESGA series
Application Fields: Electroplating
Application Machine: CNC Machine Tools
Certification: CE
Condition: New
Compressor: Hanbell or Bitzer
Evaporator: Shell and Tube
Condenser: Fin Type
Controller: Scm, PLC Is Optional
Refrigerant: R22/R407c/R404A/R134A
Expansion Valve: Danfoss/Emerson
OEM: Available
Dom: Available
Overseras Service: Available
Trademark: Eurostars
Transport Package: Standard Export Package
Specification: CE
Origin: Guangdong, Prc
HS Code: 8418692090
1.Eurostars air cooled screw type water chiller a)Low Noise
b)High Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
g)CEÂ certificated
Â
2.Eurostars Water Chiller Features-air cooled screw type water chiller
1).The Chiller cooling capacity with a widely range
2). Adopt good quality famous brand HANBELL or Bitzer compressor,high efficiency, low noise, lessÂ
  wearing and long life
3).With high efficiency condener and evaporator
4). World famous brand parts: such Danfoss/ ALCO expansion valve, FUJI contactor other brand like PUNP, Schneider,Siemens;
5). Water chillers have high COP;
6). Stable quality, long using life.Â
7).Heat recovery(optional)can help user produce free hot water, which can be 55C
8). Can be widely used in different area.
9). Strong unit base frame ensured the equipment stable operationÂ
10). Adopt leading brand PLC or SCM controller
11). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
12).Standard model exclude water tank and water pump;but it can be custom-made based on client requirement,such as including chilled water pump,hot water pump and hot water tank;
13).Refrigerant is R407C,R22,but R404A,R134A also available.
14).Power and frequency supply:380~415V-3PH-50HZ;Can customize 220~480V-3PH-60HZ;
15). Chilled water range: 5°C to 20°C
Â
3.Eurostars water chiller protection devices
1)Phase reversion protection,Â
2)Phase lack protection,Â
3)Overload current protection,
4)Discharge air temp. protection,Â
5)Low & High pressure protection,Â
6)Low temp. protection,Â
7)Water flow protection(interface reserved)
Â
Â
4.Eurostars chiller technical parameter
4.1Refrigerant-R22
<
Air Cooled Chiller Unit (Screw Type Compressor-one compressor) | |||||||||
 Model     ESGA- | 40ISTS | 60ISTS | 80ISTS | 90ISTS | 105ISTS | 115ISTS | 125ISTS | ||
Rated Cooling Capacity | KW | 143 | 204 | 273 | 322 | 373 | 403 | 444 | |
USRT | 40.67Â | 58.02Â | 77.65Â | 91.58Â | 106.09Â | 114.62Â | 126.28Â | ||
XÂ 1000Kcal/h | 122.98Â | 175.44Â | 234.78Â | 276.92Â | 320.78Â | 346.58Â | 381.84Â | ||
 Comp. lnput Power×Qty (KW) | 39.3×1 | 53.7×1 | 71.2×1 | 79.7×1 | 92.3×1 | 100.8×1 | 109.8×1 | ||
Refrigerant | R22 | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp.  protection, Low & High pressure protection, Low temp.  protection, Reserved water flow protection interface. |
||||||||
Number of Refrigeration Circuit | 1 | ||||||||
Capacity Control (%) | 0, 66, 100 | 0, 50, 75, 100 | |||||||
Refrigerant Charge (Kg) | 30 | 42 | 56 | 68 | 78 | 84 | 93 | ||
Condenser | Ripple Aluminum Fins Around Copper Pipe | ||||||||
Evaporator | Dia.of Pipe (inch) | 2-1/2" | 3" | 3" | 3" | 4" | 4" | 4" | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Chilled  Water Flow(m3/h) | 24.60 | 35.09 | 46.96 | 55.38 | 64.16 | 69.32 | 76.37 | ||
Water Pressure drop (kPa) | 28 | 33 | 48 | 55 | 61 | 64 | 66 | ||
Axial Fan | Air Flow×1000m3/h | 40.2 | 56.8 | 80.4 | 85.2 | 120.6 | 120.6 | 160.8 | |
Power×Qty (KW) | 2.0×2 | 1.2×4 | 2.0×4 | 1.2×6 | 2.0×6 | 2.0×6 | 2.0×8 | ||
Running Noise dB(A) | 68 | 68 | 68 | 68 | 72 | 72 | 72 | ||
Total Weight (Kg) | 1160 | 1730 | 2590 | 2670 | 2750 | 2930 | 3160 |
<
Air Cooled  Chiller Unit (Screw Type Compressor-two compressors) | |||||||||
 Model     ESGA- | 140IDTS | 155IDTS | 185IDTS | 195IDTS | 210IDTS | 230IDTS | 255IDTS | ||
Rated Cooling Capacity | KW | 498 | 546 | 644 | 682 | 746 | 806 | 888 | |
USRT | 141.64Â | 155.29Â | 183.16Â | 193.97Â | 212.17Â | 229.24Â | 252.56Â | ||
XÂ 1000Kcal/h | 428.28Â | 469.56Â | 553.84Â | 586.52Â | 641.56Â | 693.16Â | 763.68Â | ||
 Comp. lnput Power×Qty (KW) | 65.4×2 | 71.2×2 | 79.7×2 | 83.4×2 | 92.3×2 | 100.8×2 | 109.8×2 | ||
Refrigerant | R22 | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp.  protection, Low & High pressure protection, Low temp.  protection, Reserved water flow protection interface. |
||||||||
Number of Refrigeration Circuit | 2 | ||||||||
Capacity Control (%) | 0, 25, 37.5, 50, 62.5, 75, 87.5, 100 | ||||||||
Refrigerant Charge (Kg) | 104 | 112 | 136 | 142 | 156 | 168 | 186 | ||
Condenser |  Ripple Aluminum Fins Around Copper Pipe | ||||||||
Evaporator | Dia.of Pipe (inch) | 5" | 5" | 3"×2 | 3"×2 | 4"×2 | 4"×2 | 4"×2 | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Chilled  Water Flow(m3/h) | 85.7 | 93.9 | 110.8 | 117.3 | 128.3 | 138.6 | 152.7 | ||
Water Pressure drop (kPa) | 42 | 54 | 44 | 52 | 54 | 55 | 65 | ||
Axial Fan | Air Flow×1000m3/h | 160.8 | 160.8 | 170.4 | 241.2 | 241.2 | 241.2 | 321.6 | |
Power×Qty (KW) | 2.0×8 | 2.0×8 | 1.2×12 | 2.0×12 | 2.0×12 | 2.0×12 | 2.0×16 | ||
Running Noise dB(A) | 72 | 72 | 72 | 72 | 75 | 75 | 75 | ||
Total Weight (Kg) | 4430 | 4550 | 5340 | 5420 | 5500 | 5860 | 6320 |
<
Air Cooled Chiller Unit with Heat Recovery (Screw Type Compressor-one compressor) | |||||||||
 Model     ESGA- | 40ISVTS | 60ISVTS | 80ISVTS | 90ISVTS | 105ISVTS | 115ISVTS | 125ISVTS | ||
Rated Cooling Capacity | KW | 143 | 204 | 273 | 322 | 373 | 403 | 444 | |
USRT | 40.67Â | 58.02Â | 77.65Â | 91.58Â | 106.09Â | 114.62Â | 126.28Â | ||
XÂ 1000Kcal/h | 122.98Â | 175.44Â | 234.78Â | 276.92Â | 320.78Â | 346.58Â | 381.84Â | ||
 Comp. lnput Power×Qty (KW) | 39.3×1 | 53.7×1 | 71.2×1 | 79.7×1 | 92.3×1 | 100.8×1 | 109.8×1 | ||
Refrigerant | R22 | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp.  protection, Low & High pressure protection, Low temp.  protection, Reserved water flow protection interface. |
||||||||
Number of Refrigeration Circuit | 1 | ||||||||
Capacity Control (%) | 0, 66, 100 | 0, 50, 75, 100 | |||||||
Refrigerant Charge (Kg) | 30 | 42 | 56 | 68 | 78 | 84 | 93 | ||
Condenser | Ripple Aluminum Fins Around Copper Pipe | ||||||||
Evaporator | Dia.of Pipe (inch) | 2-1/2" | 3" | 3" | 3" | 4" | 4" | 4" | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Chilled  Water Flow(m3/h) | 24.60 | 35.09 | 46.96 | 55.38 | 64.16 | 69.32 | 76.37 | ||
Water Pressure drop (kPa) | 28 | 33 | 48 | 55 | 61 | 64 | 66 | ||
Axial Fan | Air Flow×1000m3/h | 40.2 | 56.8 | 80.4 | 85.2 | 120.6 | 120.6 | 160.8 | |
Power×Qty (KW) | 2.0×2 | 1.2×4 | 2.0×4 | 1.2×6 | 2.0×6 | 2.0×6 | 2.0×8 | ||
Running Noise dB(A) | 68 | 68 | 68 | 68 | 72 | 72 | 72 | ||
Total Weight (Kg) | 1160 | 1730 | 2590 | 2670 | 2750 | 2930 | 3160 | ||
Running Weight(Kg) | 1270 | 1920 | 2810 | 2900 | 3020 | 3240 | 3450 | ||
Heat Recovery Parameters | |||||||||
Refrigerant Charge (Kg) | 32 | 44 | 59 | 71 | 80 | 87 | 96 | ||
Heat Reclaimed Volume (kw) | KW | 43 | 61 | 82 | 97 | 112 | 121 | 133 | |
USRT | 12.20Â | 17.41Â | 23.29Â | 27.47Â | 31.83Â | 34.39Â | 37.88Â | ||
XÂ 1000Kcal/h | 36.89Â | 52.63Â | 70.43Â | 83.08Â | 96.23Â | 103.97Â | 114.55Â | ||
Heat Recoverer | Dia.of Pipe (inch) | 1-1/2" | 1-1/2" | 1-1/2" | 2" | 2" | 2" | 2" | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Reclaimed  Water Flow (m3/h) | 7.4 | 10.5 | 14.1 | 16.6 | 19.2 | 20.8 | 22.9 | ||
Water Pressure drop (kPa) | 24 | 23 | 27 | 27 | 26 | 26 | 26 | ||
Total Weight (Kg) | 1240 | 1810 | 2690 | 2770 | 3130 | 3240 | 3490 |
<
Air Cooled Chiller Unit with Heat Recovery (Screw Type Compressor-two compressor) | |||||||||
 Model     ESGA- | 140IDVTS | 155IDVTS | 185IDVTS | 195IDVTS | 210IDVTS | 230IDVTS | 255IDVTS | ||
Rated Cooling Capacity | KW | 498 | 546 | 644 | 682 | 746 | 806 | 888 | |
USRT | 141.64Â | 155.29Â | 183.16Â | 193.97Â | 212.17Â | 229.24Â | 252.56Â | ||
XÂ 1000Kcal/h | 428.28Â | 469.56Â | 553.84Â | 586.52Â | 641.56Â | 693.16Â | 763.68Â | ||
 Comp. lnput Power×Qty (KW) | 65.4×2 | 71.2×2 | 79.7×2 | 83.4×2 | 92.3×2 | 100.8×2 | 109.8×2 | ||
Refrigerant | R22 | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp.  protection, Low & High pressure protection, Low temp.  protection, Reserved water flow protection interface. |
||||||||
Number of Refrigeration Circuit | 2 | ||||||||
Capacity Control (%) | 0, 25, 37.5, 50, 62.5, 75, 87.5, 100 | ||||||||
Refrigerant Charge (Kg) | 104 | 112 | 136 | 142 | 156 | 168 | 186 | ||
Condenser |  Ripple Aluminum Fins Around Copper Pipe | ||||||||
Evaporator | Dia.of Pipe (inch) | 5" | 5" | 3"×2 | 3"×2 | 4"×2 | 4"×2 | 4"×2 | |
Water Side Max Pressure  (MPa) | 1 | ||||||||
Chilled  Water Flow(m3/h) | 85.7 | 93.9 | 110.8 | 117.3 | 128.3 | 138.6 | 152.7 | ||
Water Pressure drop (kPa) | 42 | 54 | 44 | Pet Waste Bag Making Machine Pet industry machinery and equipment, pet litter bag making machine, ultrasonic non-woven glove making machine. Craftsmanship quality, fine production, aluminum alloy bracket, not only has a reasonable and beautiful structure, but also can extend the service life of the machine. Intelligent operation, the machine automatically counts, and the product qualification rate reaches more than 99%. Dog Poop Bag Making Machine,Pet Litter Bag Making Machine,Pet Dog Poop Bag Making Machine Changzhou shanglai automation equipment co., ltd , https://www.slautomate.com |