Model NO.: L535R-1
Trademark: Shinova
Specification: ISO, CE
Origin: China
HS Code: 8421199090
Model NO.: L535R-1
Trademark: Shinova
Specification: ISO, CE
Origin: China
HS Code: 8421199090
Low Speed High Capacity Refrigerated Centrifuge(L535R-1)Â Model: L535R-1,L535-1,L535R
Â
L535R-1(normal temp.L535-1,tabletopL535R) has variety of rotors ,bucket and adaptors.It is widely used in clinical medicine, biopharmacy and cell foster.When L535R/L535R-1 reaches the highest speed, it can keep the temperature below -4ºC.The special wind deflector can keep the sample in a good state.        Â
Â
Features:Â
Various rotors, brackets and adaptors are available.
Microprocessor control, directly driven by high torque and frequency-conversion motor without carbon pollution which can prolong the service life.
Speed, time and RCF can be set freely.
9 ACC profiles and 10 DEC profiles to keep the high centrifugation efficiency.
rotective functions of overspeed, maloperation, machine self-diagnose, door interlock, stainless chamber and double protective containment structure to ensure the safety of the machine.
It is programmable and many programs can be stored.
The environmental refrigerant can keep the temperature below 4ºC at max. speed.       Â
Â
Technical Parameters:
Â
Model | L535R-1 | L535-1 | L535R |
Order No. | 151000 | 219000 | 143000 |
Max.speed | 5350r/min | 5350r/min | 5350r/min |
Max.RCF | 5030xg | 5030xg | 5030xg |
Max.Capacity | 4x750ml | 4x750ml | 4x750ml |
Speed Acurracy | ±30r/min | ±30r/min | ±30r/min |
Time setting range | 1min to 99min | Â 1min to 99min | 1min to 99min |
Temp setting range | 20ºC to 40ºC |  / | 20ºC to 40ºC |
Temp Acurracy | ±2ºC | / | ±2ºC |
Compressor | Non-CFC unit(R404a) | / | Non-CFC unit(R404a) |
Noise | <65dB(A) | <65dB(A) | <65dB(A) |
Power Supply | AC220V±22V 50Hz 16A | AC220V±22V 50/60Hz 5A | AC220V±22V 50/60Hz 10A |
Wattage | 1700w | 1100w | 1600w |
Dimension (WxDx H) | 560x660x850mm | 565x660x850mm | 710x630x440mm |
Package Dim(WxDxH) | 756x856x1320mm | 756x856x1320mm | 860x810x620mm |
Net Weight | 120kg | 98kg | 75kg |
Model: L535R-1,L535-1,L535R
Â
L535R-1(normal temp.L535-1,tabletopL535R) has variety of rotors ,bucket and adaptors.It is widely used in clinical medicine, biopharmacy and cell foster.When L535R/L535R-1 reaches the highest speed, it can keep the temperature below -4ºC.The special wind deflector can keep the sample in a good state.        Â
Â
Features:Â
Various rotors, brackets and adaptors are available.
Microprocessor control, directly driven by high torque and frequency-conversion motor without carbon pollution which can prolong the service life.
Speed, time and RCF can be set freely.
9 ACC profiles and 10 DEC profiles to keep the high centrifugation efficiency.
rotective functions of overspeed, maloperation, machine self-diagnose, door interlock, stainless chamber and double protective containment structure to ensure the safety of the machine.
It is programmable and many programs can be stored.
The environmental refrigerant can keep the temperature below 4ºC at max. speed.       Â
Â
Technical Parameters:
Â
Model | L535R-1 | L535-1 | L535R |
Order No. | 151000 | 219000 | 143000 |
Max.speed | 5350r/min | 5350r/min | 5350r/min |
Max.RCF | 5030xg | 5030xg | 5030xg |
Max.Capacity | 4x750ml | 4x750ml | 4x750ml |
Speed Acurracy | ±30r/min | ±30r/min | ±30r/min |
Time setting range | 1min to 99min | Â 1min to 99min | 1min to 99min |
Temp setting range | 20ºC to 40ºC |  / | 20ºC to 40ºC |
Temp Acurracy | ±2ºC | / | ±2ºC |
Compressor | Non-CFC unit(R404a) | / | Non-CFC unit(R404a) |
Noise | <65dB(A) | <65dB(A) | <65dB(A) |
Power Supply | AC220V±22V 50Hz 16A | AC220V±22V 50/60Hz 5A | AC220V±22V 50/60Hz 10A |
Wattage | 1700w | 1100w | 1600w |
Dimension (WxDx H) | 560x660x850mm | 565x660x850mm | 710x630x440mm |
Package Dim(WxDxH) | 756x856x1320mm | 756x856x1320mm | 860x810x620mm |
Net Weight | 120kg | 98kg | 75kg |
Boiler Steam Superheater is a coil type heat exchanger which is used to produce superheated steam or to convert the wet steam to dry steam, generated by a boiler.
It is different from a boiler in a way that, boiler utilizes both sensible heat as well as latent heat to convert water into steam while superheater utilizes only sensible heat to superheat the steam in order to increase its enthalpy.
Bare tube type steam superheater coils, plate super heaters are commonly used.
Steam Superheater,Platen Superheater,Types Of Superheater,Superheater In Boiler Diagram
Jinan Yuanda Power Equipment Co.,Ltd. , https://www.jnyuandaboilers.com