Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

Model NO.: GC5891N
Trademark: Haida
Transport Package: Strong Wooden Case
Origin: Guangdong, China
Model NO.: GC5891N
Trademark: Haida
Transport Package: Strong Wooden Case
Origin: Guangdong, China
Laboratory Gas Chromatography Instrument For Dissolved Gas In Transformer Oil
 
Description:
The entire new generation of laboratory high-end automatic gas chromatograph gc6891n, the basic international most advanced technology platform and decades of international industry technology application experience, function, reliability and application flexibility, etc. in the industry leader.

Application:
Oil extraction and refining, petrochemical, fine chemicals, food safety, environmental protection, electronic high purity gas industry, research institutes, quality inspection, safety supervision, police forensic and national security and other fields of analysis and detection.

Parameter:
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
Column temperature Box
Furnace Size 28×30×18cm
Temperature control Range higher than room temperature 5ºC~450ºC; Use liquid nitrogen cold well -80ºC~400ºC; use dry ice trap -55ºC~400ºC
Temperature setting accuracy 0.1ºC
Maximum program heating rate 120ºC/min
Maximum once method run time 999.99min
Maximum class of program heating 7 class
Programmed Temperature Rate 0.1~120ºC/min (increment 0.1 ºC)
Operation Column loss compensation (dual channel)
Heating Zone
Heating Zone
Heating Zone
6 Independent control heating zone (excluding furnace temperature control, two inlet, two detectors, two auxiliary heating areas)
Maximum operating temperature in auxiliary heating zone 300ºC
Detector
Hydrogen Flame ionization detector FID
Maximum operating temperature 450ºC
Minimum check out limit ≤2.5pgC/s [n-C16]
Dynamic linear Range ≥107(±10%)
Data acquisition Frequency 100Hz (MAX)
Thermal conductivity Pool Tester TCD
Maximum operating temperature 400ºC
Minimum check out limit <400pg C3H8/ml(He)
Dynamic linear Range 105(±5%)
Data acquisition Frequency 100Hz (MAX)
Flame Photometric Detector FPD
Maximum operating temperature 250ºC
Minimum check out limit <4pgC/sec,<1pg P/sec
Dynamic linear Range >103S,>104P
Selective <4pgC/sec,<1pg P/sec
Electronic Capture Detector ECD
Maximum operating temperature 400ºC
Detector compensation Gas Type 5% Methane/Argon or nitrogen
Minimum check out limit <0.01Ppg/s lindane
Dynamic linear Range >5×1055
Data acquisition Frequency 100Hz (MAX)
Radioactive sources <12mCi  63Ni
Nitrogen and Phosphorus detector NPD
Maximum operating temperature 450ºC
Minimum check out limit <0.2 pg N/sec,<0.2 pg P/sec
Dynamic linear Range 105N,105P
Minimum check out limit <0.3pg C/Sec
The above detectors are suitable for filling column and capillary column
Anti-control software Optional configuration (Automatic injection B6891N)
(The table parameters for the company Standard Model parameters, we support customer customization parameters)

Performance:
1.Inlet flow rate, chromatographic column load flow, detector gas flow, complete EPC control
Micro-channel Air Circuit Integrated Board
All-imported miniature proportional valves and flow/pressure sensors
Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi

2.Industry-Leading Detector design
All detectors are high-precision electronic flow/pressure control
Fit and fill column and capillary column
Special ceramic treatment of the enlarged plate, in the humid season is always stable

3.Automatic ignition, hydrogen leak automatic protection function, safe and reliable

4.Accurate furnace temperature tracking design

5.Independent Heating small column box

In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.

6.Fully Imported Valve configuration system
Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;

7.Precise temperature control of the programmed furnace
Furnace internal control accuracy less than 0.01°c
The temperature difference between the internal points is not more than the °c
Rapid heating and cooling, the highest program heating speed: 120ºC/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes
Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)

8.The convenient realization of gas cutting technology
Multi-dimensional chromatographic function to complete the separation and analysis of complex samples
It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.

9.Advanced Power Distribution Management shunt
A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply automatic Feed

10.Automatic injection
8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)

11.Automatic Online inspection function




Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

The introduction of Haida
Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.

Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

 
Packaging & Shipping:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

 
After-service:

If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.



 
Laboratory Gas Chromatography Instrument For Dissolved Gas In Transformer Oil
 
Description:
The entire new generation of laboratory high-end automatic gas chromatograph gc6891n, the basic international most advanced technology platform and decades of international industry technology application experience, function, reliability and application flexibility, etc. in the industry leader.

Application:
Oil extraction and refining, petrochemical, fine chemicals, food safety, environmental protection, electronic high purity gas industry, research institutes, quality inspection, safety supervision, police forensic and national security and other fields of analysis and detection.

Parameter:
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
Column temperature Box
Furnace Size 28×30×18cm
Temperature control Range higher than room temperature 5ºC~450ºC; Use liquid nitrogen cold well -80ºC~400ºC; use dry ice trap -55ºC~400ºC
Temperature setting accuracy 0.1ºC
Maximum program heating rate 120ºC/min
Maximum once method run time 999.99min
Maximum class of program heating 7 class
Programmed Temperature Rate 0.1~120ºC/min (increment 0.1 ºC)
Operation Column loss compensation (dual channel)
Heating Zone
Heating Zone
Heating Zone
6 Independent control heating zone (excluding furnace temperature control, two inlet, two detectors, two auxiliary heating areas)
Maximum operating temperature in auxiliary heating zone 300ºC
Detector
Hydrogen Flame ionization detector FID
Maximum operating temperature 450ºC
Minimum check out limit ≤2.5pgC/s [n-C16]
Dynamic linear Range ≥107(±10%)
Data acquisition Frequency 100Hz (MAX)
Thermal conductivity Pool Tester TCD
Maximum operating temperature 400ºC
Minimum check out limit <400pg C3H8/ml(He)
Dynamic linear Range 105(±5%)
Data acquisition Frequency 100Hz (MAX)
Flame Photometric Detector FPD
Maximum operating temperature 250ºC
Minimum check out limit <4pgC/sec,<1pg P/sec
Dynamic linear Range >103S,>104P
Selective <4pgC/sec,<1pg P/sec
Electronic Capture Detector ECD
Maximum operating temperature 400ºC
Detector compensation Gas Type 5% Methane/Argon or nitrogen
Minimum check out limit <0.01Ppg/s lindane
Dynamic linear Range >5×1055
Data acquisition Frequency 100Hz (MAX)
Radioactive sources <12mCi  63Ni
Nitrogen and Phosphorus detector NPD
Maximum operating temperature 450ºC
Minimum check out limit <0.2 pg N/sec,<0.2 pg P/sec
Dynamic linear Range 105N,105P
Minimum check out limit <0.3pg C/Sec
The above detectors are suitable for filling column and capillary column
Anti-control software Optional configuration (Automatic injection B6891N)
(The table parameters for the company Standard Model parameters, we support customer customization parameters)

Performance:
1.Inlet flow rate, chromatographic column load flow, detector gas flow, complete EPC control
Micro-channel Air Circuit Integrated Board
All-imported miniature proportional valves and flow/pressure sensors
Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi

2.Industry-Leading Detector design
All detectors are high-precision electronic flow/pressure control
Fit and fill column and capillary column
Special ceramic treatment of the enlarged plate, in the humid season is always stable

3.Automatic ignition, hydrogen leak automatic protection function, safe and reliable

4.Accurate furnace temperature tracking design

5.Independent Heating small column box

In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.

6.Fully Imported Valve configuration system
Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;

7.Precise temperature control of the programmed furnace
Furnace internal control accuracy less than 0.01°c
The temperature difference between the internal points is not more than the °c
Rapid heating and cooling, the highest program heating speed: 120ºC/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes
Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)

8.The convenient realization of gas cutting technology
Multi-dimensional chromatographic function to complete the separation and analysis of complex samples
It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.

9.Advanced Power Distribution Management shunt
A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply automatic Feed

10.Automatic injection
8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)

11.Automatic Online inspection function




Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

The introduction of Haida
Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.

Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

 
Packaging & Shipping:
Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

 
After-service:

If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.



 