Model NO.: KM4
Mounting: Ceiling Mount
Lifetime: 10~15 years
Certification: ISO, CE, CCC
Condition: New
Pipe: 2-Pipe Standard, 4-Pipe Optional
Motor: AC Standard, DC Optional
Heat Exchanger: Hydrophillic Coating
Pump Lift: 750mm
Electric Heater: Available for Option
Trademark: umbrellaclimate
Transport Package: by Carton
Specification: 340-2380 CMH
Origin: China
HS Code: 84159090
Model NO.: KM4
Mounting: Ceiling Mount
Lifetime: 10~15 years
Certification: ISO, CE, CCC
Condition: New
Pipe: 2-Pipe Standard, 4-Pipe Optional
Motor: AC Standard, DC Optional
Heat Exchanger: Hydrophillic Coating
Pump Lift: 750mm
Electric Heater: Available for Option
Trademark: umbrellaclimate
Transport Package: by Carton
Specification: 340-2380 CMH
Origin: China
HS Code: 84159090
Umbrellaclimate Hydronic Ceiling Cassette Fan Coil Unit (FCU):Description:
Designed to control the distribution of conditioned air by a 4 way louver discharge system, is the most popular solution that allows free floor or wall surfaces.
Cassette Fan Coils have been designed to control the distribution of conditioned air by a 4 way louver discharge system. These types of units are normally located in the false ceiling, with only the front panel visible. With the return air centralized adjustable louvers on the perimeter allow for airflow control in heating and cooling modes. The most popular applications are office buildings and shops. Since the installation is located in the ceiling cassettes are the preferred solution when the user wants a discreet heating and cooling solution that allows free floor or wall surfaces.
General Features:
1: Cooling capacity : 1.8-13.6(kw);
2: Air volume: 340-2380(m3/h);
3: Condensing drain pump with lift 750mm;
4: Auto swing
5: "C"type heat exchanger, blue fin
6: It is easy to maintain the fan and fan motor.
7: Float switch inside to prevent from leaking
8: Fresh air can be input from outdoor to better indoor air quality
9: Thin design unit which can be installed in a limit ceiling(the Min. Thickness is 290mm)
10:Square panels, which can be choose the direction of inlet/outlet water connection freely
11: Auxiliary duct is available to send part of air to other place, in order to improve indoor temperature air equality
FCU Optional:
1: 4 pipes system
2: External drained part
3: It is can be installed for the Electric heater
4: Easily interfaced with most widely used Mod-Bus and proprieary supervisory system based on Mod-Bus protocol
5: Remote controller is standard and wire controller is optional
6: Water drained pump can be select inside the unit (standard) or outside the unit(optional and easy to do maintain)
7: Water valve can be installed already
8: Grill is optional to prevent from hand injury
9: 1way, 4way, Circulation way air outlet for complete selection
10 brushless plastic package DC motor&EC motor Â
Cassette Fan Coil Unit View:
FCU Controller:
FCU Remote Controller Shape and Button(Standard):
Wire Wall Pad(Optional):
Â
Technical Data:
Model | FP-34KM4 | FP-51KM4 | FP-68KM4 | FP-80KM4 | FP-85KM4 | FP-102KM4 | FP-136KM4 | FP-170KM4 | FP-204KM4 | FP-238KM4 | FP-272KM4 | |||
power supply | 220V,50Hz,1Ph | |||||||||||||
air volume | H | m3/h | 340 | 510 | 680 | 800 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | 2720 | |
M | 290 | 400 | 540 | 650 | 700 | 850 | 1110 | 1400 | 1670 | 1950 | 2150 | |||
L | 200 | 290 | 400 | 500 | 550 | 680 | 860 | 1100 | 1300 | 1520 | 1600 | |||
static pressure | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
cooling capacity | TH | H | W | 1800 | 2700 | 3600 | 4200 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 | 14400 |
BTU/h | 6142 | 9212 | 12283 | 14330 | 15354 | 18425 | 24566 | 30708 | 36850 | 42991 | 49133 | |||
SH | W | 1365 | 2100 | 2790 | 3200 | 3365 | 4085 | 5702 | 6780 | 8240 | 9320 | 11400 | ||
BTU/h | 4657 | 7165 | 9519 | 10918 | 11481 | 13938 | 19455 | 23133 | 28115 | 31800 | 38897 | |||
TH | M | W | 1555 | 2341 | 3080 | 3570 | 3811 | 4510 | 6187 | 7600 | 9221 | 10513 | 12350 | |
SH | W | 1092 | 1680 | 2186 | 2500 | 2604 | 3130 | 4300 | 5301 | 6490 | 7300 | 8500 | ||
TH | L | W | 1367 | 2059 | 2700 | 3201 | 3362 | 4040 | 5515 | 6733 | 8230 | 9390 | 11000 | |
SH | W | 883 | 1316 | 1743 | 2055 | 2117 | 2532 | 3485 | 4314 | 5314 | 5857 | 6900 | ||
heating capacity | H | W | 2700 | 4050 | 5400 | 6350 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | 21600 | |
M | W | 2187 | 3210 | 4375 | 5108 | 5435 | 6550 | 8691 | 11000 | 13259 | 15300 | 17500 | ||
L | W | 1896 | 2812 | 3751 | 4396 | 4673 | 5570 | 7413 | 9319 | 11312 | 12890 | 15000 | ||
noise | H | 0Pa | dB(A) | 37 | 39 | 41 | 42 | 43 | 45 | 46 | 48 | 50 | 52 | 53 |
power input | H | 0Pa | W | 37 | 52 | 62 | 65 | 76 | 96 | 134 | 152 | 189 | 228 | 250 |
waterflow volume | Â | m3/h | 0.31 | 0.46 | 0.62 | 0.73 | 0.77 | 0.93 | 1.23 | 1.54 | 1.85 | 2.16 | 2.46 | |
water pressure dropping | kPa | 11.8 | 12.9 | 22.1 | 24.3 | 18.2 | 26.8 | 28.4 | 33.2 | 35.9 | 38.4 | 40 | ||
dimension of water(in & out)connection pipe | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
out | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | |||
coil | type | high efficient copper pipe to wear Hydrophilic aluminum coil | ||||||||||||
dimension of water drain pipe | mm | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ||
net dimension | unit | L×W×H    mm | 570*570*290 |  | 730*730*290 | 930*930*290 | ||||||||
panel | 650*650*45 | Â | 850*850*45 | 1050*1050*45 | ||||||||||
net weight | whole | kg | 24 | 24 | 26 | 27 | 33 | 34 | 34 | 40 | 41 | 42 | 43 |
a. Cooling mode: Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â b. Heating mode:Â Â Â Â Â Â Â Â Â
                       Â
- Return air temperature: 27C DB/ 19C WB.                         - Return air temperature: 20C.        Â
- Inlet/ outlet water temperature: 7C/ 12C.                          - Inlet water temperature: 50C.        Â
                                                        - Water flow-rate: same as cooling mode  Â
Â
Â
Description:
Designed to control the distribution of conditioned air by a 4 way louver discharge system, is the most popular solution that allows free floor or wall surfaces.
Cassette Fan Coils have been designed to control the distribution of conditioned air by a 4 way louver discharge system. These types of units are normally located in the false ceiling, with only the front panel visible. With the return air centralized adjustable louvers on the perimeter allow for airflow control in heating and cooling modes. The most popular applications are office buildings and shops. Since the installation is located in the ceiling cassettes are the preferred solution when the user wants a discreet heating and cooling solution that allows free floor or wall surfaces.
General Features:
1: Cooling capacity : 1.8-13.6(kw);
2: Air volume: 340-2380(m3/h);
3: Condensing drain pump with lift 750mm;
4: Auto swing
5: "C"type heat exchanger, blue fin
6: It is easy to maintain the fan and fan motor.
7: Float switch inside to prevent from leaking
8: Fresh air can be input from outdoor to better indoor air quality
9: Thin design unit which can be installed in a limit ceiling(the Min. Thickness is 290mm)
10:Square panels, which can be choose the direction of inlet/outlet water connection freely
11: Auxiliary duct is available to send part of air to other place, in order to improve indoor temperature air equality
FCU Optional:
1: 4 pipes system
2: External drained part
3: It is can be installed for the Electric heater
4: Easily interfaced with most widely used Mod-Bus and proprieary supervisory system based on Mod-Bus protocol
5: Remote controller is standard and wire controller is optional
6: Water drained pump can be select inside the unit (standard) or outside the unit(optional and easy to do maintain)
7: Water valve can be installed already
8: Grill is optional to prevent from hand injury
9: 1way, 4way, Circulation way air outlet for complete selection
10 brushless plastic package DC motor&EC motor Â
Cassette Fan Coil Unit View:
FCU Controller:
FCU Remote Controller Shape and Button(Standard):
Wire Wall Pad(Optional):
Â
Technical Data:
Model | FP-34KM4 | FP-51KM4 | FP-68KM4 | FP-80KM4 | FP-85KM4 | FP-102KM4 | FP-136KM4 | FP-170KM4 | FP-204KM4 | FP-238KM4 | FP-272KM4 | |||
power supply | 220V,50Hz,1Ph | |||||||||||||
air volume | H | m3/h | 340 | 510 | 680 | 800 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | 2720 | |
M | 290 | 400 | 540 | 650 | 700 | 850 | 1110 | 1400 | 1670 | 1950 | 2150 | |||
L | 200 | 290 | 400 | 500 | 550 | 680 | 860 | 1100 | 1300 | 1520 | 1600 | |||
static pressure | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||
cooling capacity | TH | H | W | 1800 | 2700 | 3600 | 4200 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 | 14400 |
BTU/h | 6142 | 9212 | 12283 | 14330 | 15354 | 18425 | 24566 | 30708 | 36850 | 42991 | 49133 | |||
SH | W | 1365 | 2100 | 2790 | 3200 | 3365 | 4085 | 5702 | 6780 | 8240 | 9320 | 11400 | ||
BTU/h | 4657 | 7165 | 9519 | 10918 | 11481 | 13938 | 19455 | 23133 | 28115 | 31800 | 38897 | |||
TH | M | W | 1555 | 2341 | 3080 | 3570 | 3811 | 4510 | 6187 | 7600 | 9221 | 10513 | 12350 | |
SH | W | 1092 | 1680 | 2186 | 2500 | 2604 | 3130 | 4300 | 5301 | 6490 | 7300 | 8500 | ||
TH | L | W | 1367 | 2059 | 2700 | 3201 | 3362 | 4040 | 5515 | 6733 | 8230 | 9390 | 11000 | |
SH | W | 883 | 1316 | 1743 | 2055 | 2117 | 2532 | 3485 | 4314 | 5314 | 5857 | 6900 | ||
heating capacity | H | W | 2700 | 4050 | 5400 | 6350 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 | 21600 | |
M | W | 2187 | 3210 | 4375 | 5108 | 5435 | 6550 | 8691 | 11000 | 13259 | 15300 | 17500 | ||
L | W | 1896 | 2812 | 3751 | 4396 | 4673 | 5570 | 7413 | 9319 | 11312 | 12890 | 15000 | ||
noise | H | 0Pa | dB(A) | 37 | 39 | 41 | 42 | 43 | 45 | 46 | 48 | 50 | 52 | 53 |
power input | H | 0Pa | W | 37 | 52 | 62 | 65 | 76 | 96 | 134 | 152 | 189 | 228 | 250 |
waterflow volume | Â | m3/h | 0.31 | 0.46 | 0.62 | 0.73 | 0.77 | 0.93 | 1.23 | 1.54 | 1.85 | 2.16 | 2.46 | |
water pressure dropping | kPa | 11.8 | 12.9 | 22.1 | 24.3 | 18.2 | 26.8 | 28.4 | 33.2 | 35.9 | 38.4 | 40 | ||
dimension of water(in & out)connection pipe | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
out | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | |||
coil | type | high efficient copper pipe to wear Hydrophilic aluminum coil | ||||||||||||
dimension of water drain pipe | mm | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ||
net dimension | unit | L×W×H    mm | 570*570*290 |  | 730*730*290 | 930*930*290 | ||||||||
panel | 650*650*45 | Â | 850*850*45 | 1050*1050*45 | ||||||||||
net weight | whole | kg | 24 | 24 | 26 | 27 | 33 | 34 | 34 | 40 | 41 | 42 | 43 |
a. Cooling mode: Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â b. Heating mode:Â Â Â Â Â Â Â Â Â
                       Â
- Return air temperature: 27C DB/ 19C WB.                         - Return air temperature: 20C.        Â
- Inlet/ outlet water temperature: 7C/ 12C.                          - Inlet water temperature: 50C.        Â
                                                        - Water flow-rate: same as cooling mode  Â
Â
Â
Product categories of Puffed Snack Machine, This processing line can make different kinds snacks, such as rice crusts, chips, bulges, etc.
We are specialized manufacturers with 15 years of extruder experience, we have the perfect after-sales service and technical support. Look forward to your cooperation!
Corn Puff Extruder,Snack Food Extruder Machine,Corn Snack Food Extruder,Snack Food Extruder
Jinan Chenyang Technology Co., Ltd. , https://www.cypetfoodmachine.com